Application Manual CDA3000
3  User interface and data structure
3.1.3 Characteristic 
data sets
Each user data set and the application data sets may contain a second
characteristic data set. The switch can be made to this second character-
istic data set
• by terminals
• when a frequency limit is reached
• when the direction is reversed or
• by bus access.
Online switching between characteristic data sets CDS1 and CDS2 is
possible.
The following subject areas contain parameters for the second character-
istic data set:
Reference structure:
Min., max. and fixed frequency
Driving profile generator:
Ramps
Current-controlled startup:
All parameters
VoltageFrequencyControl:
All parameters
IxR load compensation:
All parameters
Slip compensation:
All parameters
Current injection:
All parameters
Magnetizing:
All parameters
Speed controller SFC:
All parameters
Speed controller FOR
All parameters
Analog inputs
Scaling