EasyManua.ls Logo

Lust CDA3000 - 38 TX-Device Capacity Utilization

Lust CDA3000
358 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-74
Application Manual CDA3000
5 Software functions
5.3.6 _38TX-Device
capacity
utilization
(1) Acceleration
(2) Stationary operation
(3) Braking
Figure 5.28 Peak current value storage for checking of drive dimensioning
The peak current value memory continuously stores the absolute peak
values in the acceleration, stationary operation and braking phases. Also,
the mean device capacity utilization is calculated by means of a filter time
constant. When the values have been read they can be reset.
Function Effect
Display of all information of
importance for drive configu-
ration as
Peak value memory
Mean device capacity
utilization
Optimization of drive configu-
ration
Rapid fault rectification
F/Hz
t/s
t/s
CACMX
CSTMX
CDCMX
(1) (2) (3)