4-35
4  Application data sets
1
2
3
4
5
6
A
DE
EN
FR
4.4.4 ROT_4
Analog speed input with switchover to driving sets
Preset 4 for rotational drives
Figure 4.25 Control terminal assignment with ASTER = ROT_4
Function Application
• Analog speed input for two directions 
of rotation
• Adjustment of speed via correction 
value
• Selection of fixed frequencies
• Spindle
• Winding drive
• etc.
X2 Des. Function
20 OSD02/14
Relay contact
for “Ready” 
message
19 OSD02/11
18 OSD02/12
17 DGND Digital ground
16 OSD01 “Standstill” message
15 OSD00 “Reference reached” message
14 DGND Digital ground
13
U
V
Auxiliary voltage 24 V
12 ISD03 Fixed frequency 2
11 ISD02 Fixed frequency 1
10 ISD01 Start/Stop anti-clockwise
9 ISD00 Start/Stop clockwise
8 ENPO Power stage hardware enable
7
U
V
Auxiliary voltage 24 V 
6
U
V
Auxiliary voltage 24 V
5 OSA00 Actual frequency 0 ... FMAX
4 AGND Analog ground
3 ISA01 Correction value 0 V ... + 10 V
2 ISA00 Reference -10 V ... + 10 V
1
U
R
Reference voltage 10V, 10mA
+24V
H1
H2
ENPO
STL
STR
N1
K0
-
+
0 ... 10 V
R1
10 k
R2
10 k
S1
S2
14
11
12