4-28
Application Manual CDA3000
4 Application data sets
4.4.1 ROT_1
Analog speed input
Preset 1 for rotational drive
Figure 4.17 Control terminal assignment with ASTER = ROT_1
Function Application
Analog speed input for two directions
of rotation
Adjustment of speed via button
(MOP function)
Spindle
Winding drive
Vacuum pumps
Extruder
Stirrer
etc.
X2 Des. Function
20 OSD02/14
Relay contact
for Ready
message
19 OSD02/11
18 OSD02/12
17 DGND Digital ground
16 OSD01 Standstill message
15 OSD00 Reference reached message
14 DGND Digital ground
13
U
V
Auxiliary voltage 24 V
12 ISD03 Reduce speed
11 ISD02 Increase speed
10 ISD01 Start/Stop anti-clockwise
9 ISD00 Start/Stop clockwise
8 ENPO Power stage hardware enable
7
U
V
Auxiliary voltage 24 V
6
U
V
Auxiliary voltage 24 V
5 OSA00 Actual frequency 0 ... FMAX
4 AGND Analog ground
3 ISA01 Not assigned
2 ISA00 Reference -10 V ... + 10 V
1
U
R
Reference voltage 10V, 10mA
H1
H2
ENPO
S2
STL
STR
S1
N1
-
+
0 ... 10 V
R1
10 k
+24V
K0
14
11
12