4-28
Application Manual CDA3000
4  Application data sets
4.4.1 ROT_1
Analog speed input
Preset 1 for rotational drive
Figure 4.17 Control terminal assignment with ASTER = ROT_1
Function Application
• Analog speed input for two directions 
of rotation
• Adjustment of speed via button 
(MOP function)
• Spindle
• Winding drive
• Vacuum pumps
• Extruder
• Stirrer
• etc.
X2 Des. Function
20 OSD02/14
Relay contact
for “Ready” 
message
19 OSD02/11
18 OSD02/12
17 DGND Digital ground
16 OSD01 “Standstill” message
15 OSD00 “Reference reached” message
14 DGND Digital ground
13
U
V
Auxiliary voltage 24 V
12 ISD03 Reduce speed
11 ISD02 Increase speed
10 ISD01 Start/Stop anti-clockwise
9 ISD00 Start/Stop clockwise
8 ENPO Power stage hardware enable
7
U
V
Auxiliary voltage 24 V 
6
U
V
Auxiliary voltage 24 V
5 OSA00 Actual frequency 0 ... FMAX
4 AGND Analog ground
3 ISA01 Not assigned
2 ISA00 Reference -10 V ... + 10 V
1
U
R
Reference voltage 10V, 10mA
H1
H2
ENPO
S2
STL
STR
S1
N1
-
+
0 ... 10 V
R1
10 k
+24V
K0
14
11
12