5.3.5 _36 KP-KEYPAD
Figure 5.27 Display for continuous actual value display and bar graph
The continuous actual value display and bar graph can be used separa-
tely to display actual values. The bar graph is used for status display of
system values or to view trends of individual actual values.
Parameters of the KEYPAD
Function Effect
• Password settings for the
user levels
• Definition of the permanent
displays
• Protection of the inverter
module against unauthorized
access
• Selection of key actual val-
ues for permanent display
inactive (Low level)
active (High level)
VAL
OSD02
OSD01
OSD00
ISD03
ISD02
ISD01
ISD00
ENPO
Parameter Function Value range FS Unit Online
360-DISP Continuous actual value display of the KP200
see Table 5.40
406
361-BARG Bar graph display of the KP200 419
362-PSW2 Password for user level 2 of the KP200 0 ... 65535 0
363-PSW3 Password for user level 3 of the KP200 0 ... 65535 0
364-PSW4 Password for user level 4 of the KP200 0 ... 65535 0
367-PSWCT  Password for the CTRL menu of the KP200 0 ... 65535 0
368-PNUM
Activate/deactivate parameter number display of the 
KP200
ON / OFF OFF
369-CTLFA Multiplier of incremental value in CTRL menu of KP200 1 ... 65535 10000
1-MODE User level of KP200 1 ... 6 1
Table 5.39 Parameters from subject area _36KP KEYPAD