5-136
Application Manual CDA3000
5 Software functions
5.5.15 _86SY-
System
Parameters of the system
Function Effect
Performance of a device test
Triggering of a controller
reinitialization
The device is optionally reset
completely or in part to its
factory setting (FS)
Controller data and limit
values are recalculated
Parameter Function Value range FS Unit Online
4-PROG Reset device to factory setting 0 ... 65535 2
15-PLRDY Activate control initialization ON/OFF OFF
Table 5.90 Parameters from subject area _86SY-System
Explanatory notes
In the factory setting the application data set DRV_1 is activated
(see parameter list in appendix).
A control initialization is always carried out under the following con-
ditions:
Setting of ENPO signal and startup (STR or STL)
In KP200 operation:
Quitting of the subject area level in the PARA menu branch,
into the menu branch selection level (menu level). The display
shows MENU.
Activation of a control initialization by means of parameter 15-
PLRDY is only necessary when the D
RIVEMANAGER device status
indicator shows Parameter setting and the device is to adopt the
newly set values of parameters for control of the device in advance.
After the control initialization the device status is set to switch-on
inhibited/ready.
Not every parameter setting leads to the Parameter setting device
state.