Application Manual CDA3000
5-135
5 Software functions
1
2
3
4
5
6
A
DE
EN
FR
Explanatory notes
When the time MPTx elapses the inverter module switches to the
Open-loop control/Closed-loop control active state. That means
that during the magnetization phase voltage frequency control is
deactivated for a short time.
The transition can be made directly from the magnetization phase to
current injection.
The magnetization time for control modes SFC and FOR is calcu-
lated during auto-tuning (163-ENSC) and should only be altered by
highly experienced control engineers.