24 WFDIG Warning: master reference 
value incorrect
Warning message when the reference value of the 
master passed to the slave is incorrect.
(Section 5.3.9 “_50 WA-Warning messages”)
   
25 WIT Warning: ixt integrator started 
(motor)
Warning message when integrator for current I over 
time t has tripped to protect the motor.
(Section 5.3.2 “_33 MO-Motor protection”)
   
26 S_ RDY Device initialized Output is set if the device is initialized after power-
on.
   
27 C_ RDY Device ready Output is set if by setting the signal ENPO the device 
is “ready to start”, parameters for a UDS switchover 
have been completely reset and there are no error 
messages.
   
28 DCV DC-link buffering active DC link is buffered by means of power failure bridg-
ing.
(Section 5.3.4 “_34 PF-Power failure bridging”)
   
29 USER0 Reserved for modified soft-
ware
Output can be used by modified software
   
30 USER1 Reserved for modified soft-
ware
Output can be used by modified software
   
31 USER2 Reserved for modified soft-
ware
Output can be used by modified software
   
32 USER3 Reserved for modified soft-
ware
Output can be used by modified software
   
33 FMSO Reference coupling output, 
Master/-Slave operation
Output of master for reference input to slave in 
Master/-Slave coupling
(Section 5.5.7 “_66 MS-Master/-Slave operation”)
34 OCLK Clock output for reference 
input
Output for reference input via a clock frequency of 
0-10 kHz
(Section 5.2.5 “_25 CK-Clock input/ Clock output”)
BUS KP/ DM Function Effect
F
O
S
0
0
F
O
S
0
1
F
O
S
0
2
F
O
E
0
x
Table 5.21 Settings for function selector FOxxx of the digital outputs
Explanatory notes
• The warning messages are not displayed in the DRIVEMANAGER.
They can be evaluated in bit-coded form in parameter 120-WRN.
• Parameters can be set for warning limits in subject area _50WA-
Warning messages (section 5.3.9).