Application Manual CDA3000
4-53
4  Application data sets
1
2
3
4
5
6
A
DE
EN
FR
4.6.1 M-S_1
Master drive with analog guide value input
Preset 1 for Master/-Slave operation
Figure 4.36 Control terminal assignment with ASTER = M-S_1
The parameter presets for application data sets M-S_x are located as
parameter comparison references in section 4.6.5 “Comparison of para-
meters, Master/-Slave operation”.
Function Application
• Speed synchronism of several drives 
with programmable transmission 
ratio
• Inverter module is master
• Digital guide value input
• Adjustment of guide value via button 
(MOP function)
• Replacement of mechanical gears 
and line shafts (not angle-synchro-
nous)
• Winding drive
• Drafting equipment
• Trolley drive
X2 Des. Function
20 OSD02/14
Relay contact
for “Ready” 
message
19 OSD02/11
18 OSD02/12
17 DGND Digital ground
16 OSD01 Slave interface
15 OSD00 “Standstill” message
14 DGND Digital ground
13
U
V
Auxiliary voltage 24 V
12 ISD03 Reduce speed
11 ISD02 Increase speed
10 ISD01 Start/Stop anti-clockwise
9 ISD00 Start/Stop clockwise
8 ENPO Power stage hardware enable
7
U
V
Auxiliary voltage 24 V 
6
U
V
Auxiliary voltage 24 V
5 OSA00 Actual frequency 0 ... FMAX
4 AGND Analog ground
3 ISA01 Not assigned
2 ISA00 Reference -10 V ... + 10 V
1
U
R
Reference voltage 10V, 10mA
H1
ENPO
S2
STL
STR
S1
N1
-
+
DGND
Slave
X2/10
0 ... 10 V
R1
³
10 k
W
+24V
K0
14
11
12