Backing-up the device setup (150-SAVE)
With the setting 150-SAVE = START the device setup is stored in the
active user data set.
During the save operation the parameter value START is displayed; it
does not switch to STOP until the operation has been completed suc-
cessfully.
The same effect is achieved by simultaneously pressing the two cursor
keys on the K
EYPAD KP200 control unit for approx. 2 seconds while at the
menu level. At the menu level the display shows “MENU”.
Setting of application data set (152-ASTER)
Selection of the application data set defines the framework parameters of
the predefined application solutions. This special adaptation to different
preset solutions is made with parameter 152-ASTER.
When a parameter of an application data set is changed, the assistance
parameter 152-ASTER is automatically set to OFF. Parameter 151-
ASTPR for the active application data set retains its setting.
For explanatory notes on assistance parameter 152-ASTER refer to sec-
tion 4 “Application data sets”.
Note: Selectasuitableapplicationdatasetbeforesettingthe
inverter parameters for your application. Selecting the appli-
cation data set later will overwrite your parameter setting with
the fixed presets of the application data set concerned. The
only exceptions are the auto-tuning parameters.
Explanatory notes
• Parameter values resulting from the size of the current inverter
moduleareassignedanasterisk(*)inthe“Value range” and “Fac-
tory setting” columns.
BUS 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
KP/ DM
OFF DRV_ 1 DRV_ 2 DRV_ 3 DRV_ 4 DRV_ 5 ROT_1 ROT_2 ROT_3 BUS_1 BUS_2 BUS_3 M-S_1 M-S_2 M-S_3 M-S_4 ROT_4