Application Manual CDA3000
2-3
2  Inverter module CDA3000
1
2
3
4
5
6
A
DE
EN
FR
DE
EN
FR
X4 RS232 terminal For DRIVEMANAGER or KEYPAD KP200
X6 Option slot 1 e.g. for user module UM8I4O
X7 Option slot 2 e.g. for communication module
X10
Voltage supply for 
communication module 
+ 24 V, ground
X11 CAN-In / PROFIBUS-DP Bus connection input
X12 CAN-Out CAN bus connection output
X13 Address coding plug
Only for CAN
open
, Profibus DP
X15 User module UM-8I4O
Voltage supply, 
8 digital inputs, 
4 digital outputs
(1) Reset button See section 2.7
(2) Boot button See section 2.7
S1, S2 Address coding switch
Only for CAN
open
, Profibus DP
NT Designation NT Designation
Motor cable U Motor cable U
Motor cable V Motor cable V
Motor cable W Motor cable W
Grounding lead PE Grounding lead PE
Grounding lead PE Grounding lead PE
DC-link voltage + DC-link voltage +
Braking resistor Braking resistor
DC-link voltage - DC-link voltage -
Grounding lead PE Grounding lead PE
NC Mains phase L3
Neutral conductor Mains phase L2
Mains phase Mains phase L1
Table 2.2 Power terminal designation, CDA3000
No. Designation Function
Table2.1 KeytoFigure2.1