Application Manual CDA3000
5-61
5  Software functions
1
2
3
4
5
6
A
DE
EN
FR
The following temperature sensors can be set by way of parame-
ter 330-MOPTC:
Settings for 335-MOPCN
Explanatory notes
• To protect the motor, the characteristic and operation of the IEC
standard motor should generally conform to the following limit
values:
f=0Hz
≈ 30% I
N
f=25Hz ≈ 80% I
N
f
N
=50Hz ≈ 100% I
N
Consult the motor manufacturers for precise data.
BUS KP/DM Function
0 OFF Monitoring off 
1 KTY Linear PTC (KTY84, yellow)
2 PTC Threshold PTC (to DIN 44082)
3 TSS Klixon (temperature switch as break contact)
Table 5.34 Settings for 330-MOPTC Temperature sensor
Inverter module
Recommended 4-pole IEC 
standard motor [kW]
Motor rated current for motor 
protection, MOPCN [A]
CDA32003 0.375 2.0
CDA32004 0.75 3.4
CDA32006 1.1 5.1
CDA32008 1.5 6.5
CDA34003 0.75 2.0
CDA34005 1.5 3.8
CDA34006 2.2 5.6
CDA34008 3.0 7.5
CDA34010 4.0 9.1
CDA34014 5.5 11.6
Table 5.35 Motor rated current dependent on inverter module and IEC
standard motor