Application Manual CDA3000
5-113
5  Software functions
1
2
3
4
5
6
A
DE
EN
FR
Active characteristic data set display
Possibilities of characteristic data set switchover with
651-CDSSL
 Current injection All parameters
 Magnetizing All parameters
 Speed controller SFC All parameters
 Current control Reference current for control
 Speed controller FOR All parameters
BUS KP/DM Function
0 CDS1 Characteristic data set 1 (CDS1) active
1 CDS2 Characteristic data set 2 (CDS2) active
Table 5.70 Display for 650-CDSAC
BUS KP/DM Function
0 OFF
No switchover
• CDS 1 active
1 FILIM
Switchover on exceeding of frequency of value in 
parameter FILIM
• CDS 2, if frequency > FLIM, otherwise CDS 1
2 TERM
Switchover via digital input
• CDS 2, if IxDxx = 1, otherwise CDS 1
3 ROT
Switchover on reversal of direction
• CDS 2, if anti-clockwise, otherwise CDS 1
4 SIO
Switchover via SIO
• CDS 2, if control bit set, otherwise CDS 1
5 OPTN1
Switchover via field bus at option slot 1
• CDS 2, if control bit set, otherwise CDS 1
6 OPTN2
Switchover via field bus at option slot 2
• CDS 2 if control bit set, otherwise CDS 1
Table 5.71 Settings for 651-CDSSL
Subject area Parameter
Table 5.69 Subject areas with parameters in the second characteristic
data set (CDS)