Application Manual CDA3000
A-3
Appendix A  Overview of parameters
1
2
3
4
5
6
A
DE
EN
FR
_200 A-Analog output, from page 5-23 
200 FOSA0 Function selector analog output OSA00 ACTF 1 2 USIGN8 FLASH
201 OAMN0 Minimum value for analog output OSA00 0 3 3 INT16 FLASH
202 OAMX0 Maximum value for analog output OSA00 100 3 3 INT16 FLASH
203 OAFI0 Filter constant for OSA00 0 3 3 USIGN8 FLASH
204 TSCL  Nm Torque (scaling value) G 3 3 FLOAT3 2 FLASH
_21ID-Digital inputs, from page 5-27  
210 FIS00 Function selector digital standard input 
ISD00
STR 1 2 USIGN8 FLASH
211 FIS01 Function selector digital standard input 
ISD01
STL 1 2 USIGN8 FLASH
212 FIS02 Function selector digital standard input 
ISD02
SADD1 1 2 USIGN8 FLASH
213 FIS03 Function selector digital standard input 
ISD03
OFF 1 2 USIGN8 FLASH
214 FIE00 Function selector digital input IED00 
(terminal expansion)
OFF 3 3 USIGN8 FLASH
215 FIE01 Function selector digital input IED01 
(terminal expansion)
OFF 3 3 USIGN8 FLASH
216 FIE02 Function selector digital input IED02 
(terminal expansion)
OFF 3 3 USIGN8 FLASH
217 FIE03 Function selector digital input IED03 
(terminal expansion)
OFF 3 3 USIGN8 FLASH
218 FIE04 Function selector digital input IED04 
(terminal expansion)
OFF 3 3 USIGN8 FLASH
219 FIE05 Function selector digital input IED05 
(terminal expansion)
OFF 3 3 USIGN8 FLASH
220 FIE06 Function selector digital input IED06 
(terminal expansion)
OFF 3 3 USIGN8 FLASH
221 FIE07 Function selector digital input IED07 
(terminal expansion)
OFF 3 3 USIGN8 FLASH
222 FIF0  Function selector virtual fixed input 0 OFF 4 4 USIGN8 FLASH
223 FIF1  Function selector virtual fixed input 1 OFF 4 4 USIGN8 FLASH
_24OD-Digital outputs, from page 5-34 
240 FOS00 Function selector digital standard output 
OSD00
BRK1 1 2 USIGN8 FLASH
241 FOS01 Function selector digital standard output 
OSD01
REF 1 2 USIGN8 FLASH
242 FOS02 Function selector digital standard output 
OSD02 (relay)
S_RDY 1 2 USIGN8 FLASH
243 FOE00 Function selector digital output OSE00 
(terminal expansion)
OFF 3 3 USIGN8 FLASH
244 FOE01 Function selector digital output OSE01 
(terminal expansion)
OFF 3 3 USIGN8 FLASH
245 FOE02 Function selector digital output OSE02 
(terminal expansion)
OFF 3 3 USIGN8 FLASH
No. Name    Unit  Function
 Factory 
set.
Your set. R W
 Data 
type
 Memory 
type