Attention: The factory setting causes application data set 1 (traction and
lifting drive, DRV_1) to be loaded. Pay attention to the termi-
nal assignment and the functionality of the inverter module in
this operation mode.
Device reset via Reset button
Note: The Reset button is not designed for continuous operation,
and should only be used as a backup, instead of a parameter
reset. Do not press the button beyond its contact point, other-
wise it may be permanently damaged.
Device reset
The inverter module can be reset by way of the Reset button. This initi-
ates a system initialization and causes the processor to be reset.
Parameters altered only in the RAM - that is, not saved by parameter
150-SAVE from subject area _15 FC-Initial commissioning,areresetto
their original, last saved, values.
Figure 2.6 Reset button (1)
(1)
H1 H2 H3
X4
CDA3000