Application Manual CDA3000
4-15
4  Application data sets
1
2
3
4
5
6
A
DE
EN
FR
Note: After parameter setting of the user data sets the parameter
value 166-UDSSL must be changed from PARAM (K
EYPAD,
D
RIVEMANAGER) to TERM (terminal operation) and saved
accordingly (see section 5.1 “_15 FC-Initial commissioning”).
The parameter presets for application data sets DRV_x are located as
parameter comparison references in section 4.3.6 “Comparison of para-
meters, traction and lifting drive”.
Input signals
(1) DC braking torque, subject area _68HO
Figure 4.8 Example of use of the control terminal default with
ASTER=DRV_3
The output signals are presented in section 4.3.1 “DRV_1” in Figure 4.4.
User data set switchover (switchable offline)
S1 Active UDS Example
0 UDS 1 for application 1 x-axis, traction drive
1 UDS 2 for application 2 z-axis, lifting drive
Table 4.9 User data set switchover
t [ms]
   0
   0
   1
f [Hz]
v [m/s]
   0
   1
   0
   1
   0
   1
STR
STL
S1
(1)
- 303-FMAX1
303-FMAX1
270-FFIX1
590-ACCR1
592-DECR1
594-STPR1