18.5 Error code list 151
-2121 DEV_INVALID_RTC_NU-
MBER
The requested real time con-
troller is not available for this
device.
[-2121]
-2122 DMR_INTERNAL_ERROR Some kind of internal error
occurred.
More information can be
found in the .log-file or the
debug output.[-2122]
-2123 DMR_INPUT_BUFFER_T-
OO_SMALL
The user allocated input
buffer is too small to accom-
modate the result.
[-2123]
-2124 DEV_INTERNAL_ERROR Some kind of internal error
occurred in the device driver.
More information can be
found in the .log-file or the
debug output.[-2124]
-2125 DMR_LIBRARY_NOT_F-
OUND
One or more needed li-
braries are not installed on
the system.
[-2125]
-2126 DMR_FUNCTION_NOT_I-
MPLEMENTED
A called function or ac-
cessed feature is not avail-
able for this device.
[-2126]
-2127 DMR_FEATURE_NOT_A-
VAILABLE
The feature in question is
(currently) not available for
this device or driver.
This might be because
another feature currently
blocks the one in question
from being accessible. More
information can be found in
the .log-file or the debug
output.[-2127]
-2128 DMR_EXECUTION_PRO-
HIBITED
The user is not permitted to
perform the requested oper-
ation.
This e.g. might happen if
the user tried to delete user
data without specifying the
required password.[-2128]
-2129 DMR_FILE_NOT_FOUND The specified file can't be
found.
This might e.g. happen if
the current working direc-
tory doesn't contain the file
specified.[-2129]
-2130 DMR_INVALID_LICENCE The licence doesn't match
the device it has been as-
signed to.
When e.g. upgrading a de-
vice feature each licence file
is bound to a certain de-
vice. If the device this file
has been assigned to has a
different serial number then
the one used to create the li-
cence this error will occur.[-
2130]
-2131 DEV_SENSOR_TYPE_E-
RROR
There is no sensor found
or the found sensor type is
wrong or not supported.
[-2131]
-2132 DMR_CAMERA_DESCRI-
PTION_INVALID
A function call was associ-
ated with a camera descrip-
tion, that is invalid.
One possible reason might
be, that the camera descrip-
tion has been deleted(driver
closed?).[-2132]