20.4 Working with triggers 235
Figure 2: wxPropView - Logic gate setting
Note
Because there are 4 counters and 2 timers you can only add one further exposure time using one counter as
a timer.
So if you want other sequences, you have to use the counters and timers in a flexible way as show in the next
sample:
20.4.4.1 Sequence with 4 times exposure A followed by 1 time exposure B
If you have an external trigger, you can use the counter and timer to create longer exposure sequences.
For example, if you want a sequence with 4 times exposure A followed by 1 time exposure B you can count the
trigger events. That means practically:
1. Use Counter1 to count 5 trigger signals then
MATRIX VISION GmbH