VX30/VX50 Gen3/ECO50 Vacuum Excavators Operating the Vacuum Excavator 50-21
Step 12: O
pen cyclonic separation door (7), and remove debris. Close door.
Step 13: Check
air filter. Open or remove air cleaner door (8) and inspect air filter
element. If dirty, remove element and clean with low-pressure water. The
spray wand (9) may be used. Install element after it has dried.
Clean air filter element at least once daily. Replace
damaged air filter
elements immediately.
NOTICE: Do
not operate unit without air filter installed. Damage to blower will
result.
Step 14: Ensure all
personnel are clear of the spoil tank door area.
Step 15: Lower spoil tank
, then close and lock door by pressing and holding bottom
of Tank Door Open/Close Switch.
Step 16: Follow the Sh
utdown Procedure, page 23-1, and remove ignition key.
Step 17: Sec
urely store all tools and hoses before leaving the spoil disposal site.