60-42 Maintenance - 500 Service Hours VX30/VX50 Gen3/ECO50 Vacuum Systems
Blower Oil - Change
(1) Oil Fill Port
Fill at each breather port to middle of sight glass (2)
. Fill each gear end
separately. Do not fill past middle of each sight glass. Watch for leaks.
(2) Oil Sigh
t Glass
(3) Oil D
rains
Change blower oil every 500 service
hours or twice yearly.
NOTICE: Cha
nge oil more frequently if oil quality deteriorates or operating
conditions are severe.
Refer to the Blower Operation Ma
nual supplied with the machine for instructions.
WARNING: Never attempt to change or add oil while blower is running. Personal injury or equipment
failure will result. Allow unit to cool down before attempting any maintenance.