60-26 Maintenance - 50 Service Hours or Weekly VX30/VX50 Gen3/ECO50 Vacuum Systems
Pressures - Check
Fluid Pressure
View pressures on the water pressure gauge
during operation of the following tools. View standby water
pressure when tool is not in use.
Standby Water Pressure: 2900–3100 psi (200–214 bar)
Rotary Lance: 2700–3000 psi (186–207 bar)
Water System Wand: 1400–1600 psi (97–110 bar)
Potholing Tool: 1600–2000 psi (110–138 bar)
Vacuum/ Pressure
Ensure gauge is at zero when engine is OFF. If not, refer to “Vacuum Gauge - Reset,” pag
e 50-27.
When machine is in operation, full vacuum should be 14–16" (36–41 cm) HG. In high altitude locations, full
vacuum should be 12–14" (30–36 cm) HG.
When machine is in operation, pressure shoul
d be 4–6 psi (28–41 kPa).
If pressure is over acceptable r
ange, shut down machine and contact your Vermeer dealer.
If pressure is under acceptable range, contact your Vermeer dealer.