70-6 Specifications VX30/VX50 Gen3/ECO50 Vacuum Systems
Capacities
Spoils tank VX30Gen3-300: 300 gal (1136 L)
VX30Gen3-500 LT: 4
25 gal (1609 L)
VX30Gen3-500, VX50Gen3-500, 500 LT, ECO50-500: 500 gal (1893 L)
VX30Gen3-800, 800 LT, VX50Gen3-800, 800 LT, ECO50-800: 800 gal (3028 L)
Fresh water tank(s) (total) VX30Gen3-300, 500 LT, VX50Gen3-500 LT:
(2) 50 gal (379 L)
VX30Gen3-500, 800 LT, VX50Gen3-500, 800 LT, ECO50-500: (
2) 125 gal (946 L)
VX30Gen3-800G, VX50Gen3-800G, ECO50-800: (2) 205 gal (1552 L)
Water pump pressure 5.6 gpm (21.2 L/min) @ 3000 psi (207 bar)
Vacuum pump/blower 1025 cfm (29 m
3
/min)
15" (381 mm) HG; 13" (330 mm) HG in high altitude applications, with a tolerance of
+/- 1" HG
Spoil tank offload pressure 5 psi (34.5 kPA)
Fuel tank VX30, ECO50: 22
gal (83 L)
VX50: 24 gal (91 L)
Ultra low sulfur diesel (ULSD) fuel, maximum 15 ppm or 0.0015% (15 mg/kg) sulfur
content
Battery 12V, Capacity 575 amps CCA for 30 sec. @ 0°F (-18°C)
Reserve Capacity: 130
minutes of 25-amp output at 80°F (27°C)
High CFM Capacity: 950 amps CCA for 30 sec. @ 0°F (-18°C)
Reserve Capacity: 110
minutes of 25-amp output at 80°F (27°C)