VX30/VX50 Gen3/ECO50 Vacuum Excavators Transporting the Machine 30-15
Step 7: Fill the
antifreeze tank. Open Antifreeze ball valve (4).
Step 8: Open
Upper Gate/Tank Inlet valve (5).
Step 9: Start engine,
and set throttle at low speed.
Step 10: Open
Hose Reel ball valve (6).
Step 11: Tu
rn Water Pump Switch (7) on.
Step 12: VX30: Pr
ess and hold Antifreeze Switch (8).
VX50: Press and hold Antifreeze Button (9) on LCD screen.
Step 13: Watch flow
from the end of water hose. As soon as antifreeze comes out
of the hose, release Antifreeze Switch/Button.
NOTICE: Do not al
low antifreeze tank to empty. Add more antifreeze mixture to
tank if needed. Allowing water pump to run dry will result in pump damage.
Step 14: Close Hose Ree
l ball valve. Close
Upper Gate/Tank Inlet valve.