4.0 WebUI Configuration
Phone Number
Set up to six (6) different phone numbers to send SMS Alerts.
Values (phone #)
4035550123
Interval (s)
Define how often, in seconds, SMS are sent.
Values (seconds)
5 - 65535
RSSI - Low Threshold
Set the low RSSI threshold. Once the RSSI level drops below this
threshold, the IPn3G will begin to send SMS Alerts.
Values (dBm)
-99
Core Temperature (High / Low)
Set the High and Low Core Temperature thresholds, This is the
temperature of the actual module, not the air temperature around the
modem. Default values are in brackets.
Values (C)
High: 60 - 100 (80)
Low: 10 - 50 (20)
Home / Roaming Status
The IPn3G can be configured to send a warning when the unit changes
roaming status. This can be critical as often roaming data rates are
obscenely expensive.
Values (selection)
Changed / In Roaming
Changed or in roaming
Changed to roaming
Supply Voltage
Power supply issues may be able to be detected and alerts sent. Default
values are in brackets.
Values (V)
High: 7 - 36 (36)
Low: 7 - 36 (7)
Ethernet Link Status
Problems with end devices can be detected by sensing the Ethernet Link
Status.
Values (selection)
Changed / In no-link
Changed or in no-link
Changed to no-link
I/O Status
SMS alerts can be triggered by the change in status of the I/O.
Values (selection)
Only Input Changed
Only Output changed
Input or Output Changed