Notes
The test begins only if the battery capacity is 100%.
Example
[admin@MikroTik] system ups> rtc 0
UPS Monitoring
Command name: /system ups monitor
Property Description
battery-charge ( percentage ) - the UPS's remaining battery capacity as a percent of the fully
charged condition
battery-voltage - the UPS's present battery voltage. The typical accuracy of this measurement is
±5% of the maximum value (depending on the UPS's nominal battery voltage)
frequency ( percentage ) - when operating on-line, the UPS's internal operating frequency is
synchronized to the line within variations within 3 Hz of the nominal 50 or 60 Hz. The typical
accuracy of this measurement is ±1% of the full scale value of 63 Hz
line-voltage - the in-line utility power voltage
load ( percentage ) - the UPS's output load as a percentage of full rated load in Watts. The typical
accuracy of this measurement is ±3% of the maximum of 105%
low-battery - only shown when the UPS reports this status
on-battery ( yes | no ) - Whether UPS battery is supplying power
on-line ( yes | no ) - whether power is being provided by the external utility (power company)
output-voltage - the UPS's output voltage
overloaded-output - only shown when the UPS reports this status
replace-battery - only shown when the UPS reports this status
runtime-calibration-running - only shown when the UPS reports this status
runtime-left ( time ) - the UPS's estimated remaining run time in minutes. You can query the UPS
when it is operating in the on-line, bypass, or on-battery modes of operation. The UPS's remaining
run time reply is based on available battery capacity and output load
smart-boost-mode - only shown when the UPS reports this status
smart-ssdd-mode - only shown when the UPS reports this status
transfer-cause ( text ) - the reason for the most recent transfer to on-battery operation (only shown
when the unit is on-battery)
Example
When running on utility power:
[admin@MikroTik] system ups> monitor 0
on-line: yes
Page 687 of 695
Copyright 1999-2007, MikroTik. All rights reserved. Mikrotik, RouterOS and RouterBOARD are trademarks of Mikrotikls SIA.
Other trademarks and registred trademarks mentioned herein are properties of their respective owners.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the MikroTik RouterOS v2.9 and is the answer not in the manual?

MikroTik RouterOS v2.9 Specifications

General IconGeneral
BrandMikroTik
ModelRouterOS v2.9
CategorySoftware
LanguageEnglish