Use the Post Cure Unit
3-31
3
Useful Function
3
Press the key in the local mode.
4
Select the [POST CURE] by pressing the
or key.
5
Press the key.
6
By pressing the or key, determine the start
position of re-irradiating lamp light.
Enter the distance from the front edge of the table to the start
position of irradiation.
Set values : 0 to 2890mm (for JFX-1615plus, 0 to 1290mm.)
7
Press the key.
8
By pressing the or key, determine the end
position of re-irradiating lamp light.
Enter the distance from the front edge of the table to the end position
of irradiation.
Set this in consideration of the depth of the Post Cure Unit.
Set values : 0 to 2890mm (for JFX-1615plus, 0 to 1290mm.)
9
Press the key.
The setting screen of the number of irradiations is displayed.
10
By pressing the or key, set the number of
irradiations.
Set values : 1 to 50 times
By the set number of times, the Y bar goes and returns with irradiating lamp light.
11
Press the key twice.
Re-irradiating UV lamp light starts by the Post Cure Unit.
After the set number of irradiations is completed, the machine
returns to the local mode.
When [DRAWING RANGE] of the maintenance function is set to “after print”, the setting
value differs.
for JFX-1631plus : 150 to 3040mm
for JFX-1615plus : 150 to 1440mm
When [DRAWING RANGE] of the maintenance function is set to “after print”, the setting
value differs.
for JFX-1631plus : 150 to 3040mm
for JFX-1615plus : 150 to 1440mm
After ink curing, the Post Cure Unit becomes hot. Do not touch it after curing preferably.