3-32
About time to replace lamp
When time to replace the lamp has come, the machine informs you of it when
you turn on the power supply of JFX-1631/ 1615plus, by displaying the
message on the light on the screen alternately.
When this message is displayed, replace the lamp by operating procedures
below:
1
Select the “REPLACE P.CURE MODE” of the maintenance menu.
(1)Press the key in the local mode.
(2)Select the [MAINTENANCE] by pressing the or key, and press the key.
(3)Select the [REPLACE P.CURE] by pressing the or key.
(4)Press the key twice.
The Y bar moves to the front.
2
Turn off the power supply for the Post
Cure Unit located on the Y bar.
3
Press the key.
After a while, the message on the right will be displayed.
4
Press the Y bar to move it to the front.
Move it until the Y bar cannot move any more.
5
Press the key.
When you use JFX-1631/1615, the Post Cure Unit is an option.
The lamp is hot immediately after it is turned off. Wait until the lamp cools down and replace it.
Handle the lamp with care when replacing it. If not, the lamp may hit the main unit and cause a break or
an injury.
Even after the message is displayed, the lamp of the Post Cure Unit lights for a while.
However, as the amount of light becomes less, UV ink curing is poorer compared with that before
displaying the message.
FUNCTION
ENTER
ENTER
Power supply for the Post Cure Unit
ENTER
ENTER

Table of Contents