3-32
About time to replace lamp
When time to replace the lamp has come, the machine informs you of it when
you turn on the power supply of JFX-1631/ 1615plus, by displaying the
message on the light on the screen alternately.
When this message is displayed, replace the lamp by operating procedures
below:
1
Select the “REPLACE P.CURE MODE” of the maintenance menu.
(1)Press the key in the local mode.
(2)Select the [MAINTENANCE] by pressing the or key, and press the key.
(3)Select the [REPLACE P.CURE] by pressing the or key.
(4)Press the key twice.
• The Y bar moves to the front.
2
Turn off the power supply for the Post
Cure Unit located on the Y bar.
3
Press the key.
• After a while, the message on the right will be displayed.
4
Press the Y bar to move it to the front.
• Move it until the Y bar cannot move any more.
5
Press the key.
• When you use JFX-1631/1615, the Post Cure Unit is an option.
• The lamp is hot immediately after it is turned off. Wait until the lamp cools down and replace it.
• Handle the lamp with care when replacing it. If not, the lamp may hit the main unit and cause a break or
an injury.
• Even after the message is displayed, the lamp of the Post Cure Unit lights for a while.
However, as the amount of light becomes less, UV ink curing is poorer compared with that before
displaying the message.