— Material ID Material identication
Selection: ID 110
— Material name Material name
Input: max. 18 alphanumeric characters
— Set point Set point
Input: weight; adopt unit from the calibration.
— Preset Preset point for switching from coarse ow to
ne ow. Input: weight; adopt unit from the
calibration.
— Overshoot (OVS) Material overshoot
Input: Weight; adopt unit from the calibration.
— +/- tolerance Tolerance above/below set point
Input: tolerance values; adopt unit from the
calibration.
— Calming time Calming time
Input: in ms
— Restart Restart lling.
— Conguration mode Congure the mode
6 "EasyFill" application
6.1 Functions
6.1.1 General information
The "EasyFill" application is used for single-component lling.
The application allows for quick and reliable lling and emptying of containers.
The lling process can be started, stopped, canceled, and restarted via the VNC user
interface, digital inputs, OPC/Modbus, and eldbus (except CC-Link).
6.1.2 Display functions
- Display of gross, net or tare weight
- Tare/reset tare
- Set gross to zero
- Display of weight values or remote display
- Functions via digital inputs and outputs
- Information interchange via serial I/O, eldbus and network
6.1.3 Filling mode
The "EasyFill" application supports the following lling modes:
- Net lling "B1"
- Net discharge "B4"
6.2 Application menu [Start]
6 "EasyFill" application Transmitter Series PR 5220
EN-55 Minebea Intec