EasyManua.ls Logo

Minebea Intec PR 5220 Series - 6 Easyfill Application; Functions; General Information; Display Functions

Minebea Intec PR 5220 Series
235 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Filling
Material ID Material identication
Selection: ID 110
Material name Material name
Input: max. 18 alphanumeric characters
Set point Set point
Input: weight; adopt unit from the calibration.
Preset Preset point for switching from coarse ow to
ne ow. Input: weight; adopt unit from the
calibration.
Overshoot (OVS) Material overshoot
Input: Weight; adopt unit from the calibration.
+/- tolerance Tolerance above/below set point
Input: tolerance values; adopt unit from the
calibration.
Calming time Calming time
Input: in ms
Start Start lling.
Stop Stop lling.
Restart Restart lling.
Abort Abort lling.
Conguration
Conguration mode Congure the mode
6 "EasyFill" application
6.1 Functions
6.1.1 General information
The "EasyFill" application is used for single-component lling.
The application allows for quick and reliable lling and emptying of containers.
The lling process can be started, stopped, canceled, and restarted via the VNC user
interface, digital inputs, OPC/Modbus, and eldbus (except CC-Link).
6.1.2 Display functions
- Display of gross, net or tare weight
- Tare/reset tare
- Set gross to zero
- Display of weight values or remote display
- Functions via digital inputs and outputs
- Information interchange via serial I/O, eldbus and network
6.1.3 Filling mode
The "EasyFill" application supports the following lling modes:
- Net lling "B1"
- Net discharge "B4"
6.2 Application menu [Start]
6 "EasyFill" application Transmitter Series PR 5220
EN-55 Minebea Intec

Table of Contents

Related product manuals