EasyManua.ls Logo

Minebea Intec PR 5220 Series - Connecting Analog Load Cells and Platforms

Minebea Intec PR 5220 Series
235 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Example:
Voltage output
When the output 1 is active (true), the output voltage drops from 24/12 V DC to <3 V DC.
* The load resistance must be 2.2/1 k.
4.4.7 Connecting analog load cells and platforms
4.4.7.1 General information
Load cells can be connected to the device doing the following:
- One load cell directly, see Chapter 4.4.7.2 and 4.4.7.3
- several load cells in the junction box via connecting cable, see Chapter 4.4.7.4 and
3.4.1
Note:
The colors listed here are valid for the Minebea Intecload cells and connection cables of
type "PR "
Color code
bk = black
bu = blue
gn = green
gy = gray
rd = red
wh = white
For additional information on the connection of load cells and junction boxes refer to
the corresponding installation manuals.
Transmitter Series PR 5220 4 Device installation
Minebea Intec EN-38