21-4. Fusing Unit Malfunction
Abnormal fusing temperature trouble (C0500, C0510, C0520) is detected
under any of the following timings:
a) C0500: Warming-up Failure
*
The surface temperature of the Upper Fusing Roller does not reach
50°C within 30 seconds.
*
The surface temperature of the Upper Fusing Roller does not reach
100°C within 30 seconds after it has reached 50°C.
*
The surface temperature of the Upper Fusing Roller does not reach
160°C within 40 seconds after it has reached 100°C.
*
The surface temperature of the Upper Fusing Roller does not reach
200°C within 40 seconds after it has reached 160°C.
b) C0510: Abnormally Low Fusing Temperature
*
The surface temperature of the Upper Fusing Roller remains 135°C or
less for a consecutive 1-second period after the copier has completed
warming up.
c) C0520: Abnormally High Fusing Temperature
*
The surface temperature of the Upper Fusing Roller remains 220°C or
more for a consecutive 1-second period after the copier has completed
warming up.
M-75