1-5. C0400: Exposure Lamp’s failure to turn ON
C0410: Exposure Lamp turning ON at abnormal timing
PWB-A
LA1
1139T023AA
CN7
PWB-H
PU1
TF2
Symbol Name
LA1 Exposure Lamp
TF2 Exposure Lamp Thermal Fuse
PWB-A Main Control Board
PWB-H AE Sensor Board
PU1 Power Supply Unit
1139C10TAA
T-48