2-6. Imaging Unit
(1) Disassembly, Cleaning, and Replacement and Starter Changing of
the Imaging Unit
1. Remove the Imaging Unit from the copier.
2. Remove two screws to remove the Imaging Unit Cover.
3. Unplug the Counter connector.
5. Remove two screws and one Drum Pin to remove the
PC Drum.
7. Tilt the Developing Unit to remove the developer.
4. Remove one screw to remove the PC Drum Charge
Corona Unit.
Replacement of the PC Drum
Whenever the PC Drum has been replaced, be sure
to make the "Adjustments of the Optimum Exposure
Setting in the Manual and Auto Mode." See pp. D-51
to D-52.
NOTE
Replacement of the Toner Scattering Prevention Plate
6. Remove one screw and one shoulder screw to remove
the Toner Scattering Prevention Plate.
D-27