32
MAIN DRIVE MOTOR M2 MALFUNCTION
M2
Main Drive Motor's
Lock Signal
1sec 1sec
Start of Check
1139T30MCA
1139T31MCA
M2
Main Drive Motor's
Lock Signal
1sec 1sec
Start of Check
1139T31MCA
1139C35MAA
A defective Main Drive Motor M2 is detected under any of the following
timings.
a) C0000: Main Drive Motor’s Failure to Turn
The M2 Lock signal remains HIGH for a
consecutive 1-second period after 1
second after M2 has been energized.
b) C0001: Main Drive Motor Turning at Abnormal Timing
The M2 Lock signal remains LOW for a
consecutive 1-second period while M2
remains deenergized. The check is
started after 1 second after M2 has been
deenergized.
M-93