2
PAPER TRANSPORT FAILURE
1. Paper Misfeed
When a paper misfeed occurs in the copier, the corresponding Misfeed Location Monitor LED on the
control panel blinks to let the user know where the misfeed has occurred. If an LED lights up
steadily, it indicates that there might be a sheet of paper present at that particular location in the
copier. If a paper misfeed occurs very frequently, carry out the necessary troubleshooting
procedures according to the location of the misfeed.
Blinking
LED
Misfeed Location
➁
Copier take-up and vertical transport
➂
Paper Feed Cabinet take-up and vertical transport
➀
Bypass port
➄
Transport/Separator
➅
Fusing/Exit
➆ ➈
Duplex Unit vertical transport
➇
Duplex Unit storage
➂
Duplex Unit take-up
➉
Sorter/Staple Sorter
➃
Automatic/Duplexing Document Feeder
∗
: When option is installed
∗
∗
∗
∗
∗
∗
1139T025AA
10 6 5 1
2
3
7
9
4
8
Blinking
Light
There is a misfeed at
that location.
Steady
Light
There might be a
sheet of paper
stopped at that
location.
T-2