13. Remove two screws and two compression coil springs
to remove the Synchronizing Roller Unit.
14. Remove the Synchronizing Roller.
15. Using a brush, whisk the dust and dirt off the Filter.
11. Using a soft cloth dampened with alcohol, wipe clean
the Paper Separator Fingers.
Cleaning of the PC Drum Paper Separator Fingers
12. Using a soft cloth dampened with alcohol, wipe clean
the Ds Positioning Collars.
Cleaning of the Paper Dust Remover
Cleaning of the Ds Positioning Collars
When removing the Synchronizing Roller Unit, use
care not to lose the compression coil springs. At
reinstallation, fit the close-coiled end of the springs to
the bosses on the Imaging Unit.
NOTE
Replacement of the Toner Antispill Mylar
16. Remove two screws to remove the Bias Seal.
(No Bias Seals are mounted in the copiers for the
U.S.A., Canada, and Europe.)
17. Remove two screws to remove the Toner Antispill
Mylar and replace the Mylar.
D-29