(6) Adjustment of the Manual Bypass Table Reference Position
Requirement
Ready a test chart (A3 or 11" × 17") as shown on the
left. Draw a line on the chart at a point 20 mm from
the right edge as shown.
Dimension A on the copy should measure
20 ±2.0 mm.
1. Place the test chart face down on the Original Glass
and align its rear left corner with the marker on the
Original Width Scale on the left side of the platen.
Then, lower the Original Cover.
2. Using the Manual Bypass Table, make two full size
copies.
3. Using the second copy, compare the position of the
reference line on the copy with that on the test chart.
4. If the line does not meet the requirement, loosen the
two screws that secure the Manual Bypass Table and
move the Table as necessary in the direction of the
arrows.
If dimension A on the copy is smaller than 18 mm,
move the Table to the front. If it is more than 22 mm,
move the Table to the rear.
When an Automatic or Duplexing Document Feeder
is mounted, it involves changing the Original Glass.
This in turn results in the position of the Original
Length Scale being slightly shifted toward the rear.
This is corrected by installing the Original Positioning
Plate.
NOTE