19 F30 X X An ATDC Sensor malfunction
20 F79 X X A Paper Empty Sensor malfunction
21 FE1 X X
An Original Size Detecting Sensor
malfunction
22 b10 X X
An ST-101 Paper Clamp Unit moving
malfunction
23 b30 X X
An ST-101 Paper Aligning Motor
malfunction
24 b50 X X An ST-101 Staple Unit malfunction
25 b60 X X An ST-101/S-104 Bin moving malfunction
26 d00 X X An AD-3/PF-1D Guide Plates malfunction
27 d20 X X
An AD-3/PF-1D entrance port switching
failure
28 d50 X X An Duplex Drive Motor malfunction
29 E1 X X A starter charging failure
30 E2 X X
An ATDC automatic adjustment/IU Fuse
blowing failure
31 Ar1 X X Copier watchdog (circuit protector)
32 Ar2 X X AF-3/AFR-7 watchdog (circuit protector)
33 Ar3 X X ST-101/S-104 watchdog (circuit protector)
Setting Procedure
(1) With the copier in the state ready to enter a particular Tech. Rep. Mode, press "7" to set the
copier into the Malfunction Counter Mode.
(2) Press the Paper Select Key, and the first malfunction count, which is not zero, appears on
the Multi-Copy Display. Press the Paper Select Key to obtain the count of each Malfunction
Counter whose count is not zero. After all counts have been shown, the copier is then ready
to receive a clear command.
Clearing a Malfunction Counter
(1) Press the Paper Select Key to show the count of the Malfunction Counter to be cleared on
the Multi-Copy Display.
(2) Press the Clear Key to clear the count.
*
If no malfunctions have occurred, the Zoom Ratio Indicator shows "ALL" and the
Multi-Copy Display "0".
S-20