6 COMMUNICATION FUNCTIONS
6.3 Remote Operation
303
6
Operation with RUN contact
Set the X device to be set as the RUN contact at MT Developer2.
[R series common parameters] [Motion CPU module] [CPU parameter] "Operation related setting" "RUN
contact"
The settable device range is "X0 to X2FFF". Operations are performed with the set RUN contact ON/OFF and remote RUN/
STOP status.
If the RUN contact is OFF, the status of the Motion CPU will be RUN. By executing a remote RUN/STOP in the RUN status,
the Motion CPU RUN/STOP status can be switched.
If the RUN contact is ON, the status of the Motion CPU will be STOP. The status of the Motion CPU will be STOP, even if
remote RUN is performed in the STOP status.
The "[Rq.1120] PLC ready flag (R: M30000/Q: M2000)" can also be turned ON/OFF ("PCPU READY
complete flag (SM500)" ON/OFF) in the following methods.
RUN/STOP switch change