APPENDICES
Appendix 2 Event List
423
A
Event history list
The following table lists events related to the Motion CPU.
Event
code
Event
type
Event
category
Detected event Description Detailed information
Detailed
information 1
Detailed
information 2
Detailed
information 3
0100 System Information Link-up The Motion CPU has been entered
into the link-up state as a result of
operation such as connection of the
network cable from an external
device.
Operation
source
information
Communication
speed and
communication
mode
0110 TCP connection
communication start/
end
Communication with an external
device through TCP connection has
been started. Or, communication
with an external device through TCP
connection has been terminated.
Communication
status
0120 FTP connection start/
disconnection
FTP connection with an external
device has been started. Or, FTP
connection with an external device
has been disconnected.
0130 Receive frame error A receive frame error has been
detected.
0140 SNTP server time
synchronization failure
Time setting by the time
synchronization function time has
been failed because there was no
response from the SNTP server.
07FA G-code control system
information
During G-code control, a detailed
code event has occurred.
G-code control
information
07FB Machine control
system information
During machine control, a detailed
code event has occurred.
Machine control
information
07FC Override ratio "0" The override ratio is "0" when
starting.
The override ratio was changed to
"0" when controlling.
Axis control
event
information
07FD Operation cycle
change
Operation cycle will be changed to
the time (measured) [s]
automatically because the servo
amplifier which unsupported to
setting operation cycle (time (setting
value) [s]) has been connected.
Time
information
07FE Home position return
request OFF to ON
*1
Home position return request is ON. Home position
return
information
07FF Disconnect normal
connection with
SSCNET(/H)
*2
SSCNET(/H) communication has
been disconnected by connection
function or re-connection after
disconnecting function.
SSCNET(/H)
communication
information
Communication
status
0800 Warning Link-down The Motion CPU has been entered
into the link-down state as a result of
operation such as disconnection of
the network cable from an external
device.
Operation
source
information
Communication
speed and
communication
mode
0904 Socket
communications send
error
Sending a message over socket
communication failed.
0906 Alive check error Alive check of the target device
could not be completed within the
period specified by the response
monitoring timer value.

Table of Contents