7 DIGITAL OSCILLOSCOPE
7.6 Sampling Functions
343
7
Saving sampling results
Data sampled with the digital oscilloscope is stored in the Motion CPU internal memory, and when sampling is complete,
sampling results are saved to the standard ROM or to an SD memory card.
Sampling results save destination
The sampling results save destination is specified from the following.
"Standard ROM" cannot be specified if the save destination for the sampling settings file is SD memory card.
Save destination folder and file name
Sampling results are stored to a sampling results output folder in the specified save destination (standard ROM or SD memory
card), and the system time (hexadecimal notation) is output as the file name in 8 digits when outputting sampling results.
*1 Elapsed time (seconds) up to the current time using Greenwich Mean Time 00:00:00, January 1st 1970 as the reference.
Sampling settings file save destination Settable save destination
Standard ROM • Standard ROM (trigger sampling only)
• SD memory card
SD memory card • SD memory card
Save destination folder Save file name (system time
*1
)
\data\oscout** ********.csv
Sampling
target
Buffer capacity
Sampling results output
Saved file
Standard ROM/SD memory card
<Settings>
Setting data
CH1
CH2 CH3
1st sampling point
2nd sampling point
n
th
sampling point
Results are saved from
the buffer to the
standard ROM or a
SD memory card.
*: If saving to the standard
ROM, only one stored
file is saved.