17
MANUAL PAGE ORGANIZATION
Representation of numerical values used in this manual
■Axis No. representation
In the positioning dedicated signals, "n" in "M3200+20n", etc. indicates a value corresponding to axis No. as shown in the
following table.
• The range of axis No.1 to 16 (n=0 to 15) is valid in the R16MTCPU. The range of axis No.1 to 32 (n=0 to 31) is valid in the
R32MTCPU.
• Calculate as follows for the device No. corresponding to each axis.
For axis No. 32 in Q series Motion compatible device assignment
M3200+20n ([Rq.1140] Stop command)=M3200+2031=M3820
M3215+20n ([Rq.1155] Servo OFF command)=M3215+2031=M3835
In the positioning dedicated signals, "n" in "M10440+10n", etc. of the "Synchronous encoder axis status", "Synchronous
encoder axis command signal", "Synchronous encoder axis monitor device" and "Synchronous encoder axis control device"
indicates a value corresponding to synchronous encoder axis No. as shown in the following table.
• Calculate as follows for the device No. corresponding to each synchronous encoder.
For synchronous encoder axis No.12 in Q series Motion compatible device assignment
M10440+10n ([St.320] Synchronous encoder axis setting valid flag)=M10440+1011=M10550
D13240+20n ([Md.320] Synchronous encoder axis current value)=D13240+2011=D13460
Axis No. n Axis No. n Axis No. n Axis No. n Axis No. n Axis No. n Axis No. n Axis No. n
1 0 9 8 17 16 25 24 33 32 41 40 49 48 57 56
2 1109181726253433424150495857
3 2 11 10 19 18 27 26 35 34 43 42 51 50 59 58
4 3 12 11 20 19 28 27 36 35 44 43 52 51 60 59
5 4 13 12 21 20 29 28 37 36 45 44 53 52 61 60
6 5 14 13 22 21 30 29 38 37 46 45 54 53 62 61
7 6 15 14 23 22 31 30 39 38 47 46 55 54 63 62
8 7 16 15 24 23 32 31 40 39 48 47 56 55 64 63
Synchronous encoder axis No. n Synchronous encoder axis No. n Synchronous encoder axis No. n
105498
2165109
32761110
43871211