338
7 DIGITAL OSCILLOSCOPE
7.3 Digital Oscilloscope Specifications
7.3 Digital Oscilloscope Specifications
The digital oscilloscope specifications are shown in the following table.
Individual sampling setting specifications
*1 Refer to device list for the range of devices that can be set. (Page 75 Device List)
Function Specification
Sampling settings data storage target Standard ROM, SD memory card
Sampling type Trigger sampling
Sampling start setting User operation
Sampling interval Operation cycle, 0.222ms sampling rate interval
No. of channels Word data Up to 16 channels
Bit data Up to 16 channels
Word size 2 bytes With sign/Without sign
4 bytes With sign/Without sign
Sampling target Word data Servo control data Selected from probe item list.
Motion dedicated device
Advanced synchronous control device
Optional device Word device
*1
Bit data Motion dedicated device Selected from probe item list.
Advanced synchronous control device
Optional device Bit device
*1
Trigger Number of sampling points Up to 133120 points (default: 8192 points)
Trigger mode No trigger
Data conditions OR condition, AND condition
Setting when
trigger mode is
data conditions
Trigger pattern (bit) No setting, OFF, ON, OFF ON (leading edge), ON OFF (trailing edge)
Trigger pattern (word) No setting, increase direction, decrease direction, increase or decrease
direction
Trigger reference value (word trigger
only)
Specified in data type range for each channel.
Filter specification 0 to 10000 ( rate ms)
Saving Sampling results save destination Standard ROM, SD memory card
File format CSV
Real-time display Channels
capable of real-
time display
Word Up to 8 channels
Bit Up to 8 channels