5 FUNCTIONS USED WITH SSCNET COMMUNICATION
5.6 Connection of SSCNETIII/H Head Module
199
5
SSCNETIII/H head module parameters
Set the parameters used for connecting the SSCNET/H head module.
Servo network settings
Set "LJ72MS15" for the amplifier setting in the servo network settings, and set the "RIO axis No.", "Station No. d", and "RIO
axis label". (Page 66 Amplifier setting)
Parameter setting of SSCNETIII/H head module
Set the parameters to use the SSCNET/H head module.
[Motion CPU Common Parameter] [Head Module]
• The number of SSCNET/H head module stations that can be connected to a SSCNET/H line according
to operation cycle settings, are as follows.
■Axis No.
Display the SSCNET/H head module RIO axis No. and RIO axis label settings set in the servo network settings.
(For Motion SFC programs, this number is used for specifying).
Item Setting range
Amplifier setting Amplifier information Amplifier model LJ72MS15
Axis information RIO axis No. R64MTCPU: 601 to 608
R32MTCPU: 601 to 608
R16MTCPU: 601 to 604
Station No. d 1 to 64
RIO axis label Up to 32 characters
Item Setting range Default
value
Axis No. 601 to 608
Refresh device setting (CPU side)
(Input: RX, RWr/Output: RY, RWw)
Device name Bit device name/Word device name
Module I/O No./10H(**) 00 to FF
Points Bit device: 16 to 512
Word device: 1 to 32
Start Bit device/Word device
Status device Bit device/Word device
Monitor device Word device
Command device Bit device/Word device
Operation cycle [ms]
0.888 Up to 4 stations
Up to 2 stations
Up to 1 stations0.222
0.444
Stations connected