58
2 COMMON PARAMETERS
2.2 R Series Common Parameter
Module Parameter
Specify local node settings and security in order to communicate with external devices with the Motion CPU PERIPHERAL I/F.
[R Series Common Parameter] [Motion CPU Module] [Module Parameter]
Local node setting
■IP address setting
• IP address
Set the local node IP address.
• Subnet mask
Set the IP address in order to set which upper bit to use for the network address to identify the network.
• Default gateway
Set the IP address for the passing device (default gateway) used to access the network device to which the local node
belongs.
Security
■IP filter setting
Data set at GX Works3 is read by MT Developer2, and therefore there is no need to set the IP filter.
■Disable direct connection to MELSOFT
Set whether to "Enable" or "Disable" a direct connection (simple connection) with the Engineering Tool.
■Do not respond to search for CPU module on network
Set whether to "Respond" or "Not respond" to an Engineering Tool network CPU module search.
Item Setting range Default value
Local node
setting
IP address
setting
IP address 0.0.0.1 to 223.255.255.254 192.168.3.39
Subnet mask 0.0.0.1 to 255.255.255.254/blank No setting
Default gateway 0.0.0.1 to 255.255.255.254/blank No setting
Security IP filter setting IP filter use or not Use/Not used Not used
IP filter setting Up to 32 settings No setting
Disable direct connection to MELSOFT Enable/Disable Enable
Do not respond to search for CPU module on
network
Response (no check)/Not responded (check) Response (no check)