Indicates that the elevator is travelling at low speed for longer than the time
set by parameter I-04, and that in the meantime stopping switch signal did
not activate. Since the above error may occur as a result of copying error
(stopping switch) elevator must do a first travel again. It is necessary to reset
the control disconnecting power supply or using the reset button on LC100-
D terminal.
Indicates that the elevator is traveling at releveling speed for longer than the
time set by parameter I-05, and that in the meantime stopping switch signal
did not activate. It is necessary to reset the control disconnecting power
supply or using the reset button on LC100-D terminal.
Indicates that the temperature measured by the processor on LC100-C
board rose above the value set by parameter I-12.
Indicates the elevator brake deactivation error. Brake control is done over
mechanical contact on input FI-224.
Elevator door error messages:
Indicates a door A opening failure:
- If there are end-switch – Elevator door A were not opened until end-
switch, FI-260 in time set by parameter D-13.
- If there are no end-switch – after opening sequence, system continues
to have the information from safety circuit that the door is closed .
Indicates a door B opening failure:
- If there are end-switch – Elevator door B were not opened until end-
switch, FI-270 in time set by parameter D-21.
- If there are no end-switch – after opening sequence, control cabinet
continues to have the information from safety circuit that the door is
closed.
Indicates a failure closing the door A which means that the door A is not
closed until end-switch FI-261 if it exists, or to safety circuit contact if there
is no end-switch.
Indicates a failure closing the door B which means that the door B is not
closed until end-switch FI-271 if it exists, or to safety circuit contact if there
is no end-switch.
Indicates a landing door contact failure. After the information about cabin
door closed over the end-switch FI-261 or FI-271 within 3 seconds did not
activate landing door signal from safety circuit.
Indicates a cabin door A contact failure. After closing the cabin door A, the
system has recieved information on the end-switch FI-261, and within 3
seconds was not activated cabin door A closed signal from safety circuit.
Indicates a cabin door B contact failure. After closing the cabin door B, the
system has recieved inormation on the end-switch FI-261, and within 3
seconds was not activated cabin door B closed signal from safety circuit.
Indicates a landing door locking failure, that occurs:
- At the door with mechanical locking 3 seconds after closing the door
- At the door with electrical locking 3 seconds after door locking output
signal FO-48.