SECTION 2: SAFETY INSTRUCTIONS T200 User's Manual
PAGE 2-7
A mains circuit breaker must be installed with this equipment and be accessible to the user.
This circuit breaker shall be sized such that it provides adequate r.m.s protection based on primary voltage and power
rating (kW) of the T200 system. Surge tolerance and single phase protection should also be considered.
All external d.c. supply voltages used with the T200 Series Controllers
must be derived from a Safety Extra Low Voltage (SELV) supply as
defined by standard EN60950. Such SELV voltages do not exceed a
value of 60 Vd.c. or 42.4 Va.c. peak under normal conditions and are
supplied by circuits which are separated from all hazardous voltage
conductors by permitted safety methods such as reinforced insulation.
All external electrical wiring connected to this equipment must be
colour coded in accordance with European Standard EN 60204-1
requirements. (Refer Section 2.6 of this manual).
All wires and cables entering and leaving the IP54 rated enclosures or
cabinets containing the T200 Power Supply, Controllers and Regen
resistor(s) must be protected and anchored in accordance with the
requirements of EN 60204-1. (Refer to Section 2.6 of this manual).
Required for
CE-Compliance
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Moog T200 and is the answer not in the manual?

Moog T200 Specifications

General IconGeneral
BrandMoog
ModelT200
CategoryServo Drives
LanguageEnglish

Related product manuals