T200 User's Manual SECTION 3: WIRING AND INSTALLATION
PAGE 3-54
Figure 3.31:- T200-610 and T200-710 Regeneration Resistor Option 4:- two C09838-010 (Mounting and Connection)
Regeneration
Resistor
Option/
Continuous
Rating
Actual
Continuous
Regen. Power
Peak Regen
Power
Fuse
Part Number
Fuse
Holder
Regen
Resistor
Part
Number
Regen
Resistor
Kit Part
Number
AWG/(mm
2
)
Wiring to
connect
regen resistor
Option 1
(10/750W)
600W 14kW C09762-012-
000
DIN Rail
1)
B81493-007 C22654-007
(US only)
20AWG/
(0.60mm
2
)
Option 2
(8/1,5kW)
1,25kW 18kW C09762-015-
000
DIN Rail
1)
B81493-002 C22654-011
(US only)
14AWG/
(2.0mm
2
)
Option 3
(Two of 8/
1.5kW in
parallel)
2,5kW 36kW C09762-025-
000
DIN Rail
1)
B81493-002 C22654-025
(US only)
14AWG/
(2.0mm
2
)
Option 4
(Two of 10/
1kW in
parallel)
2kW 28kW C09762-012-
000
Fuse Block A76178-003 Two of
C09838-010
(Europe only)
2.5mm
2
Table 3.6:- T200-610 and T200-710 Regeneration Resistor Options
1)
Mechanical dimensions see page 3-55