Troubleshooting
Problem
Correction
Cause
8-22 October 2019 16K PLUS
None
The Power slide will not return immediately after
pushing the bales back, if there is a full load on
the machine. The power slide will return after
squeezing the Alignment Arms to secure the load.
Use “Measure - Outputs” menu to check amperage
going to the Power Slide valve. The monitor should
display a positive amperage when moving the
power slide back, and a negative amperage when
returning the power slide. (If there is a broken wire
or shorted wire to the valve, the monitor may show
an error message.)
Use procedure described in “Checking Valve
Solenoids” to check the operation of the valve.
Adjust the speed the the function in the “Adjust -
Speed Adjustments” menu. Typically, the valve will
require a minimum of 600 milliamps to just barely
open the valve, and 1150 milli-amps to open the
valve fully.
The speed of these functions can be limited by
adjusting the Rocker Stop on the Valve Body. See
“Limiting the Bed Speed”.
Power Slide Back/Return
Function operates too fast/
slow
Crash Avoidance
Auto Mode
Check current output
Check valve solenoid
Hitch, Alignment Arms, Power
Slide, Loader
Bed, Push Off, Grab Hooks