4-42 Manual # 42-02-2223
Final Adjustment
Safety Tests
iControl provides highly automated safety testing. Before running any tests, the car must be
properly balanced and adjusted. From the iView Safety Tests screen (View > Safety Tests), the
following tests may be run:
• Car/Counterweight Safety Test, page 4-44
• Electrical Governor Test, page 4-44
• Contract Overspeed Test, page 4-45
• Inspection Overspeed Test, page 4-45
• Car/Counterweight Buffer Test, page 4-45
• Leveling Overspeed Test, page 4-47
• Emergency Brake Test, Unintended Motion, page 4-47
• Ascending Car Overspeed Test, page 4-50
• Normal Terminal Switch Overspeed Tests - Level 1, page 4-52
• Emergency Terminal Switch Overspeed Tests, page 4-53
• Normal Terminal Switch Position Tests, page 4-53
• Emergency Terminal Switch Overspeed Test, page 4-54