Machine Room Preparation
iControl AC
2
Machine Room Preparation
When preparing the machine room, consider:
Machine room environment
Ethernet and internet access
Environmental Considerations
Ambient temperature should remain within 32° to 104° Fahrenheit (0° to 40° Celsius).
Temperatures outside these guidelines may be tolerated, but will shorten equipment life.
Adequate ventilation is required. Air conditioning may be necessary.
The air in the machine room should be free of excessive dust, corrosive elements, and
excessive moisture. A NEMA 4 or NEMA 12 enclosure can help meet these requirements if
machine room conditions are inadequate.
Very high levels of radio frequency (RF) radiation from nearby sources should be avoided.
RFI may interfere with controller components, degrading elevator performance. Using
hand-held communication devices close to the controller may also cause interference.
Interference from permanently installed radio transmitting antennas is not common.
Power line voltage fluctuation should not be greater than ±10%.
If any areas in the machine room are subject to vibration, they should be avoided or rein-
forced to prevent equipment from being adversely affected.